The error message means that it is impossible for Microstran to orient the section axes because you have specified an illegal/impossible reference node or axis. Microstran uses a third node (C) to orient the section axes. With the A and B nodes for the member, C forms a plane in which the member local y axis is located - this is what's normally the section YY axis.

Smart Bracelet User ManualUser Manual Introduction

A free, mean and lean way to create data driven PDF on the fly by using SQL server reporting service (SSRS) The Microstran User s Manual is on-line through Help. Bentley Microstran Advanced 09.20.01.35 offers design of members to several steel design codes including AS 3990, AS 4100, NZS 3404, AS/NZS.

By default, Microstran assigns a reference axis to each member - columns usually use -X (global) and other members -Y or -Z, whichever is up. With a reference axis, the C node is effectively at an infinite distance along the axis. Driver Marvell Libertas 88w8335 Windows 7. Your error would occur if you specified a column with the up axis being the reference axis. The error message means that A, B, and C do not form a plane, but rather, they are collinear. RE: Microstran V8 (Structural). Thanks engsys! Im just playing around with a complex frame which I remember back in my University days (not an actual job!), which turns out to be a critical form structure (i.e.

A mechanism for small displacements), so should have no solution! (a simple hexagon pinned at the external nodes and diagonal internal bracing to all external nodes). Turns out that way after doing what you suggested. Pardon my ignorance But shouldn't the reference node/axis be in the default mode already?

And what was the specified node/axis before I made it the default axis anyway? RE: Microstran V8 (Structural) 13 Jan 08 17:13.

COPYRIGHT NOTICE (C) Copyright Engineering Systems 1997-2012. All rights are reserved. The copyright applies to this manual and to the corresponding software (together referred to herein as the “licensed material”). DISCLAIMER Subject to limitations imposed by law, Engineering Systems makes no warranty of any kind in connection with the licensed material. Engineering Systems shall not be liable for any errors contained in the licensed material nor for any incidental or consequential damages resulting from the use of the licensed material.

Engineering Systems is not engaging in the provision of consulting services in supplying the licensed material. Users of the licensed material are advised that output from computer software should be subjected to independent checks. Engineering Systems reserves the right to revise and otherwise change the licensed material from time to time without notification, or provision of revised material. SOFTWARE LICENCE The software is supplied to the user under licence.

It may be installed on as many computers as required but the number of concurrent users must not exceed the number of licences held. For network licences, use is permitted only in the country for which the licence was supplied. The software may not be sub-licensed, rented, or leased to another party. The licence can only be transferred to another party on payment of a transfer charge determined by Engineering Systems. Engineering Systems Pty Ltd 14 Eastern Road PO Box 85 Turramurra NSW 2074 Australia T e l: + 6 1 2 9 4 8 8 9 6 2 2 F a x: + 6 1 2 9 4 8 8 7 8 8 3 E-m ail: sup por t@m icr ost ran.com.au W eb: w w w.m ic r os tr an.c om.a u July, 2012. Microstran is a comprehensive software package for the analysis and design of all kinds of frame structures – beams, trusses, frames, towers, and bridges.